      I had some DAX 3.2 workflows with internal rc, and therefore I remove the replica properties from my pegasusrc. The only settings I had were:

      pegasus.catalog.site=XML3
      pegasus.catalog.site.file=sites.xml

      pegasus.dir.useTimestamp=true
      pegasus.dir.storage.deep=false

      The workflow now fails in the registration jobs:

      2010-11-04 07:43:15.529 ERROR [root] class java.lang.RuntimeException You need to specify the pegasus.catalog.replica property
      2010-11-04 07:43:15.530 WARN [root] non-zero exit-code 1

      I'm wondering if we should either disable registration when no rc is defined, or, set up a default empty rc.